FACILITIES

High Performance Liquid Chromatographs

Centrifuges

Gas Chromatography

Gel Permeation Chromatography

Particle Size Analyzers

Barrier Property Analyzers

le
 

Separations Cluster

High Performance Liquid Chromatographs

 

 



Varian 500-MS Ion Trap  

Contact: Thames-Rawlins
Research Group


Varian 500-MS Ion Trap

Enhanced Charge Capacity provides the 500-MS LC with the capability to detect trace amounts in a high concentration of coeluting analytes in heavy matrices. Temperature programmable SelecTemp™ API interface reduces contamination. Unidirectional triple resonance scan method preferentially ejects trapped ions toward the detector. TurboDDS™ Data dependent scanning option allows MSn for automated qualitative analysis. Varian’s Mass ID™ deconvolution software aids in the molecular weight determination of large molecules that are detected as multiply-charged ions, such as proteins, peptides and oligonucleotides. The Varian 500-MS LC Ion Trap is the instrument of choice for high-throughput LC/MS analysis where sensitivity, reliability and productivity are essential. Sensitivity enhancements include SelecTemp™, the unique temperature programmable API (Atmospheric Pressure Ionization), enabling optimal analysis of thermally labile compounds. All of these technical capabilities lead to the remarkable performance and productivity delivered by the Varian 500-MS LC ion trap. SelecTemp’s programmable temperature control delivers optimum drying gas temperatures at every time point throughout a complex analysis. Additional SelecTemp API benefits include reduced interface contamination, improved throughput, simplified setup and easily recordable parameters for GLP purposes. Premium scanning and the power of MSn Achieve unit mass resolution with uncompromised qualitative and quantitative results for narrow or coeluting chromatographic peaks at scan speeds of up to 15,000 Da/sec with the patented ‘unidirectional triple resonance’ scan method that preferentially ejects all the trapped ions toward the detector. The fast scan speed is complemented by rapid ion polarity switching of 200 milliseconds to accommodate the optimum detection of ion polarity for every analyte in the sample. Enhanced qualitative information is delivered by the 500-MS with MSn operation to n=10, expanding the spectral information content for structure elucidation.

top

 

 



Waters Gel Permeation Chromatograph and
High Performance Liquid Chromatograph


Contact: Thames-Rawlins
Research Group


Waters Gel Permeation Chromatograph and

High Performance Liquid Chromatograph
Model: Micromax/Micromax RF

Waters 515 HPLC pump with Eppendorf dual column heater Waters 2414 RI detector, Polymer labs 1000 evap light scattering detector (ELSD), & Perkin Elmer LC 295 UV-Vis Detector.

Waters 1525 Binary HPLC pump with Reverse (C18) or Normal (Silica Gel) Phases Waters 2414 RI detector, Polymer labs 1000 evap light scattering detector, & Perkin Elmer LC 295 UV-Vis Detector

The Waters binary 1525 pump is an integrated, high-pressure HPLC pump that feature on-board pulse dampening and efficient mixing. Their pulse-free solvent flow makes them the perfect choice for use with highly sensitive detectors. The Waters 515 HPLC Pump combines the most important aspects of eluent delivery for HPLC: high precision, reliability, smooth eluent flow, and proven performance. The 515 Pump is the heart of the Waters 515 Series HPLC systems. Available in isocratic, gradient, and semi-preparative configurations, Waters 515 Series systems offer industry standard performance in traditional, component-based HPLC systems.

The Polymer Labs 1000 Evaporative Light Scattering Detector (ELSD) is able to deliver high performance for demanding HPLC or GPC applications. The nebulizer and evaporator can be operated at very high temperatures to efficiently handle high boiling point solvents commonly used in GPC that other ELSDs simply cannot manage. This ELSD combines universal detection for non-volatile compounds, compatibility with high boiling point solvents, high sensitivity, rapid equilibration, eluent flow up to 5ml/min, easy-to-use software control, compact design, and easy connection to any HPLC system. Features include wide temperature range, heated transfer line, gas save function, and unique solvent recovery.

top

 

 

 

 

Centrifuges

 

 


IEC Centra CL2 Centrifuge

Contact: Robson Storey
Storey Research Group

Thermo Electron Corporation IEC Centra CL2 Benchtop

Compact, simple, and economical benchtop centrifuge designed for basic research and clinical applications.

Product Detail

The IEC Centra CL2 is an ideal system for blood separations with a capacity of up to sixteen (16) 13 mm Becton Dickenson Vacutainer ® tubes and tissue culture with up to 8 x 15 ml or 4 x 50 ml Falcon / Corning Conical tubes in sealed carriers. A simple interface allows rapid setting of critical parameters. ADDITIONAL PRODUCT FEATURES:

  • Exclusive autoclavable Aerocarrier ® adapters contain aerosols consistent with OSHA's bloodborne pathogen rule. Adapters can be removed from rotor for transport, and easily sealed with screw-on, transparent lids.
  • Simple panel membrane is glove friendly; large LED display shows current run conditions.
  • Accurate microprocessor control, with g-force run control and 30 minute At-Speed timer ensures consistent centrifugation regardless of run size.
  • Compatible with existing rotors from earlier IEC centrifuge platforms (e.g., the IEC Clinical)

top

 

 



IEC Micromax/Micromax RF

Contact: Mohamed Elasri
Department of Biology


Thermo Electron Corporation

IEC Micromax/Micromax RF

Model: Micromax/Micromax RF
The IEC Micromax/Micromax RF delivers superior separating power in less time. Micromax reaches forces up to 21,000 xg at speeds of 15,000 rpm on 24 (1.5-2.0 mL) samples or 48 (0.5 mL) microtubes in less than 15 seconds.

More Separating Power and Less Maintenance The IEC Micromax/MicromaxRF microcentrifuge produces forces up to 21,000 xg at speeds of 15,000 rpm on 24 (1.5-2.0 mL) samples or 48 (0.5 mL) microtubes. IEC Micromax's brushless motor is designed for longevity and requires no maintenance. All controls are microprocessor based for added reliability.

More Flexibility and More Convenience The IEC Micromax includes a choice of g-force or rpm speed control, gentle and fast acceleration and braking rates, audible end of run signal, as well as momentary spin and time hold selections. A "glove friendly" membrane control panel with digital display makes it easy to clean and to operate. Repeat runs are as simple as touching a single membrane switch.

Less Noise, Less Space and Less Time Other less powerful microcentrifuges are noisy distractions, but the IEC Micromax operates at a quiet 55 BA at full speed, so you can work while Micromax works. Only 12 inches wide, this machine requires less bench space than the majority of microcentrifuges (particularly refrigerated) with comparable sample capacity and power. It takes less than 15 seconds to attain 21,000 xg or to brake allowing you to process more samples per day.

Unique Polypropylene Microtube Rotors Virtually impervious to chemical attack and may be repeatedly autoclaved without damage. New sealed rotor provides aerosol containment, and can be removed from the Micromax (seal intact) and opened under an environmental hood.

top

 

 

Gas Chromatography

 

 


Varian CX Series Star 3400
Gas Chromatograph


Contact: Robson Storey
Storey Research Group

Varian CX Series Star 3400
Gas Chromatograph

Gas chromatography involves a sample being vaporized and injected onto the head of the chromatographic column. The sample is transported through the column by the flow of inert, gaseous mobile phase. The column itself contains a liquid stationary phase which is adsorbed onto the surface of an inert solid. This GC is an FID TSD Gas Chromatograph with 120 Volts and 50/60 Hzs.

top

 

 



Perkin Elmer Auto-system XL
Gas Chromatograph


Contact: Marek Urban
Urban Research Group


Perkin Elmer Auto-system XL

Gas Chromatograph

This Perkin-Elmer Autosystem XL gas chromatograph has PE-5 capillary column installed with a split/splitless injector and one detector-FID.

The gas chromatograph is employed to study the composition of volatile substances such as solvent mixtures. It is used for the quality control both of raw materials and of finished products. The vapours of the solvent mixture are forced to pass through a very thin tube usually 30 meters long (called column); they are transported by a constant flux of an inactive gas, usually nitrogen. The sides of the tube are covered with a particular substance. Different solvents have different degrees of " attraction " towards the substance that covers the sides of the tube. So the solvents more "attracted" to the tube will be moving at a slower pace, whereas those that have less attraction will be the first ones to exit the tube. A detector placed at the end of the tube calculates the time necessary for every solvent exit. Every solvent has its constant time characteristic. Therefore, it is possible to identify the solvent according to the time it needs to exit the tube.

top

 

 



Thermo-Electron Trace 2000
Gas Chromatograph
with Dual FID


Contact: Thames-Rawlins
Research Group


Thermo-Electron Trace 2000

Gas Chromatograph with Dual FID

The TRACE GC UltraTM is built around the recognized quality, reliability and ruggedness of the established TRACE GC. Ultra performance, reliability, and usability make this a must-have GC for any laboratory. Automated features result in a tremendous increase in sample throughput, with analyses performed up to 30 times faster than before, without compromises in precision.

top

 

 



Hewlett Packard 6890 Gas
Chromatograph / 5972A MSD


Contact: Thames-Rawlins
Research Group


Hewlett Packard 6890 Gas

Chromatograph / 5972A MSD

Hewlett Packard - 6890 GC including: 6890 with Purge Packed Inlet, Twin Flame Ionization Detector (FID) and Tekmar 7000/7050 Headspace Autosampler, HP 6890 is an Agilent GC. The HP 6890 Series gas chromatograph system delivers high levels of performance. The HP 6890 series GC features electronic pneumatics control of all gas pressures and flows. Onboard sensors automatically compensate for ambient temperature changes and barometric pressure differences to routinely achieve more accurate and reproducible results. By providing stable results, EPC reduces recalibration frequency and improves laboratory productivity. Includes auto sampler.

top

 

 



Hewlett Packard 5890A GC
with Diffusion Setup


Contact: Sergei Nazarenko
Sergei Nazarenko's Page


Hewlett Packard 5890A GC
with Diffusion Setup

HP 5890A GC, Split/Splitless Injector, Single Detector FID or TCD single FID, capillary column, electronic integrator.

top

 

 



Varian Star 3600 CX

Contact: Kenneth Mauritz
Mauritz Research Group


Varian Star 3600 CX

Gas chromatography involves a sample being vaporized and injected onto the head of the chromatographic column. The sample is transported through the column by the flow of inert, gaseous mobile phase. The column itself contains a liquid stationary phase which is adsorbed onto the surface of an inert solid. This GC is an FID TSD Gas Chromatograph with 120 Volts and 50/60 Hzs.

top


 

 



Agilent Technologies 6890N
Network GC System
with Diffusion Setup


Contact: Sergei Nazarenko
Sergei Nazarenko's Page


Agilent Technologies 6890N Network GC System

with Diffusion Setup

At the forefront of Agilent analytical solutions is the 6890N network gas chromatograph (GC). Built-in local area networking (LAN) allows you to share business and scientific data across sites--for fast and informed decision making. Just as its 6890 GC predecessors, this GC has all the flexibility and performance needed for research and method development in any industry. It is also rugged and reliableperfect for routine methods that require multiple columns or valves, specialty inlets or detectors, or a broad temperature range. This GC system offers proven, fourth-generation electronic pneumatics control (EPC) that keeps pressure and flow setpoints constant from run to run. This technology enables retention time locking, which allows reproduced retention times within hundredths or even thousandths of a minute on any other Agilent 6890 GC with EPC or 6850 GC, regardless of operator, location, detector, or column length. Features include fast installation and configuration, quick method setup, with simplified parameter entry and system control, a large range of inlets, including the Agilent programmable temperature vaporizing inlet, large-volume injection, eliminating sample concentration steps, and built-in Agilent 7683 automatic liquid sampler control capabilities. You simply add the injector and tray modules for high throughput, ambient headspace, micro liquid-liquid extraction, and a broad range of injection volumes Several alternative sample introduction techniques, including headspace, purge and trap, and valving. There is a choice of the industry's most sensitive detectors, including the micro-electron capture detector

An enhanced flame photometric detector (FPD) that has five times the sensitivity for sulfur and 15 times the sensitivity for phosphorus compared to the previous version and the best sensitivity for both S and P compared to other standard FPDs. A variety of data-handling choices, including Agilents Cerity ta Networked Data System for Chemical QA/QC, Cerity Networked Data System for Pharmaceutical QA/QC, and the Agilent ChemStation Plus family (which includes ChemStore C/S and ChemAccess). Everything you need for fast GC, giving you highly accurate and consistent resultsten times faster than standard GC. Includes a built-in regulatory compliance.

top

 

 

Gel Permeation Chromatography

 

 


Waters Alliance 2695 Gel
Permeation Chromatograph


Contact: Robson Storey
Storey Research Group

Waters Alliance 2695 Gel
Permeation Chromatograph

Waters Alliance 2695 Separations Module GPC with THF mobile phase and Waters 2487 dual wavelength absorbance (UV) detector, a Waters 2410 refractive index (RI) detectors, and a Wyatt Mini-DAWN laser light scattering detector.

Waters Alliance 2695 GPC with HFIP mobile phase and Waters 2410 refractive index (RI) detector.

top

 

 



Waters Alliance 2695 Gel
Permeation Chromatograph


Contact: Marek Urban
Urban Research Group


Waters Alliance 2695 Gel Permeation Chromatograph

Waters Alliance 2695 Separations Module GPC with THF mobile phase. Utilizes a Waters 2487 dual wavelength absorbance (UV) detector, a Waters 2410 refractive index (RI) detectors, and a Polymers Labs GPC column.

top

 

 



Waters Gel Permeation
Chromatograph and HPLC


Contact: Thames-Rawlins
Research Group


Waters Gel Permeation Chromatograph and HPLC

Waters 515 HPLC pump with Eppendorf dual column heater Waters 2414 RI detector, Polymer labs 1000 evap light scattering detector (ELSD), & Perkin Elmer LC 295 UV-Vis Detector

Waters 1525 Binary HPLC pump with Reverse (C18) or Normal (Silica Gel) Phases

Waters 2414 RI detector, Polymer labs 1000 evap light scattering detector, & Perkin Elmer LC 295 UV-Vis Detector.

The Waters binary 1525 pump is an integrated, high-pressure HPLC pump that feature on-board pulse dampening and efficient mixing. Their pulse-free solvent flow makes them the perfect choice for use with highly sensitive detectors.

The Waters 515 HPLC Pump combines the most important aspects of eluent delivery for HPLC: high precision, reliability, smooth eluent flow, and proven performance. The 515 Pump is the heart of the Waters 515 Series HPLC systems. Available in isocratic, gradient, and semi-preparative configurations, Waters 515 Series systems offer industry standard performance in traditional, component-based HPLC systems.

The Polymer Labs 1000 Evaporative Light Scattering Detector (ELSD) is able to deliver high performance for demanding HPLC or GPC applications. The nebulizer and evaporator can be operated at very high temperatures to efficiently handle high boiling point solvents commonly used in GPC that other ELSDs simply cannot manage. This ELSD combines universal detection for non-volatile compounds, compatibility with high boiling point solvents, high sensitivity, rapid equilibration, eluent flow up to 5ml/min, easy-to-use software control, compact design, and easy connection to any HPLC system. Features include wide temperature range, heated transfer line, gas save function, and unique solvent recovery.

top

 

 



Viscotek TDA 302 GPC

Contact: Charles McCormick
McCormick Research Group


Viscotek TDA 302 Gel Permeation Chromatograph

Triple Detector Array

Viscotek TDA 302 Gel Permeation Chromatograph Triple detector array with RI, laser light scattering, and viscosity detectors. This GPC utilizes a DMF mobile phase and Agilent pump.

The Triple Detector Array (TDATM) is used as a method for characterizing natural and synthetic polymers and proteins. The TDATM employs a concentration detector, viscometer and light scattering detector acting in concert, with each detector providing complimentary but different information. In a single GPC experiment, obtain: absolute molecular weight, molecular size, intrinsic viscosity, conformation, and structure.

The new TDATM combines the power of traditional triple detection with all new UV/VIS and Low Angle Light Scattering (LALS) options. Measure concentration with an RI, UV or both. When used simultaneously, the RI and UV provide information necessary for the determination of

LALS, a breakthrough in light scattering technology, is the only GPC detection method that provides absolute molecular weights without extrapolation or correction. Operating at an angle of 7° (degrees), LALS directly measures molecular weight for an extensive range of natural and synthetic polymers and proteins.

top

 

 



Gel Permeation Chromatograph

Contact: Charles McCormick
McCormick Research Group


Gel Permeation Chromatograph

Gel Permeation Chromatograph with a Wyatt Technologies Optilab DSP Interferometric Refractometer (RI detector), a Polymer Labs LC 1200 UV-Vis detector, and a DAWN Enhanced Optical System (DAWN® EOS) 18-angle light scattering detector for chromatography. The DAWN EOS uses a 30mW Gallium-arsenide 690nm laser light source. It also contains a flow-to-batch conversion kit, thermostatic control options, depolarization options, and interfacing options. This GPC utilizes an Agilent pump and an aqueous mobile phase. This instrument is used for characterization of synthetic polymers.

top

 

 

 

 

Particle Size Analyzers

 

 


Microtrac UPA 250
Particle Size Analyzer


Contact: Thames-Rawlins
Research Group

Microtrac UPA 250
Particle Size Analyzer

Particle Size Analyzer - Includes a sub-micron analyzer with dynamic light scattering detector It is used for liquid samples and can detect particle size 10 micron and lower.

top

 

 



Microtrac (SRA)
Particle Size Analyzer


Contact: Thames-Rawlins
Research Group


Microtrac (SRA) Particle Size Analyzer

Particle Size Analyzer - Range 0.7 - 780 microns, with powder (dry) and liquid capabilities. Measurement Technique is laser diffraction analysis.

top

 

 



Microtrac Nanotrac 250
Particle Size Analyzer


Contact: Marek Urban
Urban Research Group


Microtrac Nanotrac 250

Particle Size Analyzer

The Microtrac Nanotrac 250 has a range of 0.8 to 6500 nanometers (0.0008 to 6.5 microns). The repeatability is 1% for 100nm polystyrene. It has fixed laser and detector positions; with a 780 nm semiconductor laser directed to sample through a fiber optic cable. Alignment of optics is never needed. The measurement angle is 180 Degrees. It comes with a solid-state optical bench, Pentium IV computer, CRT or flat screen monitor, complete data management software, and printer options. Advanced Microtrac FLEX Software offers unparalleled capability for graphics, data export/import, customized printed reports, and all data handling demands including export to Adobe PDF, as well as other export formats for sharing data over the internet. FLEX software provides data storage in Microsoft Access® database format utilizing OLE. Volume, number, area and intensity weighted distributions as well as percentile and other summary data. Data integrity is ensured using FDA 21CFR Part 11 compliant security features. It handles powders, fluids and all particles suspended or suspendable in fluid. Samples may be measured by dipping probe directly into sample using Nanotrac 250. Compatible with any organic solvent and most acids and bases generally used to deliver particulate samples. Typical analysis time is 30 to 120 seconds.

top

 

 



Zetasizer Nano Series
Dynamic Light Scattering
Detector


Contact: Charles McCormick
McCormick Research Group


Zetasizer Nano Series Dynamic Light Scattering Detector

The new Zetasizer Nano series is ideal for protein characterization. The user friendly software includes customizable protein specific reports, a solvent builder library, and protein utilities to assist with the interpretation of data. The new technology incorporated in these systems delivers unequalled sensitivity and versatility. Protein size NIBS/DLS technology enables measurements of protein molecules down to 0.3nm hydrodynamic radius (equivalent to less than 1 kDa). Highest sensitivity - 0.1 mg/ml Lysozyme, for larger molecules even lower concentrations can be detected. Low sample volume - only 12µl sample volume are required and hence only small amounts of protein, and the sample can be recovered. Precision temperature control Peltier elements provide software controlled temperature range from 2°C to 90°C for accurate temperature scans.

Absolute molecular weight - An avalanche-photodiode detector and fiber detection optics give the sensitivity and stability required for absolute molecular weight measurement. The Zetasizer Nano S provides a powerful, easy to use protein characterization tool for every laboratory. All systems are compatible with the MPT-2 autotitrator to enable trend measurements and sample preparation to be automated. In principle, any small ˜particle™ can be measured using DLS - if sufficient light is detected and the particles are diffusing freely. For sub-nanometer particles, however, the level of scattered light, even at high concentrations is usually so small that only the most sensitive experimental setup can detect them. In this application note cholesterol (MW 387Da) in butanone, is prepared at 20 mg/mL. The hydrodynamic radius is found to be 0.3nm, or 3 Angstroms. This value agrees with expectations for this molecular weight range.

top

 

 

Barrier Property Analyzers

 

 


Mocon Ox-Tran Model 2/21
Oxygen Permeability


Contact: Sergei Nazarenko
Sergei Nazarenko's Page

Mocon Ox-Tran Model 2/21 Oxygen Permeability

The Barrier Properties laboratory utilizes gas and vapor transmission measurements, as well as thickness measurements to calculate permeation rates through various materials. Flat films, flexible packages, and non-flexible packages can be evaluated by any of the following techniques:

Oxygen Transmission Rate (O2TR) Testing can be performed on flat films, as well as flexible and rigid packages. Testing may be conducted under a range of relative humidity conditions at a range of temperatures. One side of the film is exposed to the oxygen permeant. As it solubilizes into the film and permeates through the sample material, nitrogen sweeps the opposite side of the film and transports the transmitted oxygen molecules to the coulometric sensor. This value is reported as a transmission rate. When this rate is multiplied by the average thickness of the material, the results are considered a permeability rate. Typical applications might include packaging for the beverage and fresh food storage industry, as well as pharmaceutical packaging.

top

 

 


Mocon Aromotron Solvent
Vapor Transport Unit


Contact: Sergei Nazarenko
Sergei Nazarenko's Page

Mocon Aromotron Solvent Vapor Transport Unit

The Barrier Properties laboratory utilizes gas and vapor transmission measurements, as well as thickness measurements to calculate permeation rates through various materials. Flat films, flexible packages, and non-flexible packages can be evaluated.

top

 

 



Mocon Permatran-W 3/31
Water Vapor Permeability


Contact: Sergei Nazarenko
Sergei Nazarenko's Page


Mocon Permatran-W 3/31

Water Vapor Permeability

Water Vapor Transmission Rate (WVTR) Testing is performed on flat films, as well as flexible and rigid packages. Testing is conducted under a range of relative humidity conditions at a range of temperatures. One side of the film is exposed to the water vapor permeant. As water solubilizes into the film and permeates through the sample material, nitrogen sweeps the opposite side of the film and transports the transmitted water vapor molecules to the calibrated infrared sensor. The response is reported as a transmission rate: when multiplied by the average thickness of the material, the result is a permeability rate.

Typical applications include packaging for the beverage and fresh food storage industry, as well as pharmaceutical packaging and auto manufacturing.

top

 

 



Mocon Permatran-W 3/33
Water Vapor Permeability


Contact: Sergei Nazarenko
Sergei Nazarenko's Page


Mocon Permatran-W 3/33

Water Vapor Permeability

PERMATRAN-W® Model 3/33 is a water vapor transmission rate (WVTR) testing system designed to assess barrier materials used in packaging applications. By testing barrier materials for WVTR under a range of conditions, these systems enable you to select the best packaging material, at the best cost. The data assures that product shelf-life and certain packaging characteristics will be met when introduced to the market.

top



top
   
 
Google
  ©2005 MRSEC at The University of Southern Mississippi