Synthesis Cluster
Microwave Plasma Reactor

Contact: Marek Urban
Urban Research Group
Microwave Plasma Reactor
Microwave plasma reactors have been utilized for surface modification of polymeric materials. These materials have a specific monomer which allow for surface functional groups. Such functional groups can be used for any surface reactions to develop stimuli-responsive polymeric surfaces.
Features:
- Power: 600W
- Frequency: 2.45GHz
- Reaction times: 5 ~ 30 sec.
- Pressure: 50 ~ 250 mTorr
top
FTIR Reaction Monitoring Systems
|
|

Mettler Toledo 4000
React IR
Contact: Thames-Rawlins
Research Group
|
Mettler Toledo 4000 React IR
ReactIR™ technology provides a real-time, dynamic picture of chemistry under actual reaction conditions. Using highly specific mid-infrared spectroscopy, ReactIR™ enables both the identification and monitoring of critical reaction species and follows the changes in the reaction on a second-by-second basis.
top |
|
|

Mettler Toledo ReactIR™iC10
Contact: Thames-Rawlins
Research Group
|
Mettler Toledo ReactIR™iC10
ReactIR iC10 is a portable, mid-infrared tool which builds upon the established foundation of ReactIR™ technology. ReactIR™iC10 serves the needs of organic and process chemists as a universal reaction analysis tool. This robust collection of technologies addresses daily monitoring issues as well as problematic reactions associated with: low temperature, elevated pressure, toxicity, corrosion, transient intermediates, moisture, and air sensitivity. These chemistries are either difficult or impossible to monitor by off-line methods, but chemistries approach routine with in situ technologies such as ReactIRTM. This mid-infrared tool is ideally suitable for the following application areas: Reaction Start/End Points, Reaction Progression, Intermediates, Concentration (Yield/Conversion), Kinetics, and Mechanism. The ReactIR™iC10 provides an ergonomic and agile solution for in situ reaction analysis. Because of the sealed outer enclosure design, the ReactIR™iC10 can be used within a fume hood. Coupled with a flexible FiberConduit TM and our patented 6 mm DiCompTM probe technology, interfacing to conventional round-bottom flasks could not be easier
top
|
High Temperature Reaction Calorimeter
|
|

Melter Toledo RC1e
High Temperature
Reaction Calorimeter
Contact: Thames-Rawlins
Research Group
|
Mettler Toledo RC1e High Temperature Reaction Calorimeter
The RC1e Reaction Calorimeters are actually both - models of a semibatch reactor from the plant and at the same time, reaction calorimeters. It allows the measurement and control of important process parameters. The RC1e also allows the determination of the complete mass and heat balance over the course of the entire chemical process. The lab batches are performed on a milliliter to liter scale under conditions which closely mirror the (pilot) plan reality.
The RC1e Reaction Calorimeter is recognized as the industrial standard to gain safety data for a later scale-up to pilot plant or production. The very robust construction guarantees a long product life, and hence, a solid protection of your investment.
top
|
Synthesis Setups
|
|


Synthesis Setup
Contact: Thames-Rawlins
Research Group
|
Synthesis Setup
Synthesis setup using a Cole-Parmer Masterflex L/S Variable-Speed Console Drive and run by Dow Camille 2000 software. Camile is a personal computer-based system for data acquisition and control.
top |
|
|

Synthesis Setup
Contact: Marek Urban
Urban Research Group
|
Synthesis Setup
Synthesis Setup using a Kd Scientific syringe pump and a Cole-Parmer Masterflex L/S Variable-Speed Console Drive run by Camile TG 4.0 software. Camile is a personal computer-based system for data acquisition and control.
top |
High Pressure Reactor
|
|

PFAULPLER, Sybron Corp
High Pressure Reactor
Contact: Thames-Rawlins
Research Group
|
PFAULPLER, Sybron Corp
High Pressure Reactor
This reactor enables work at high pressures and temperatures with large volumes. The reactor is equipped with temperature and stirrer control, gas inlet and gas recycling within the reactor. It also has liquid or gaseous sampling outlets for monitoring the reaction.
top
|
Liquid Handler
|
|

Beckman Coulter Biomek FX
Liquid Handler
Contact: Robert Lochhead
Robert Lochhead's Page
|
Beckman Coulter Biomek FX
Liquid Handler
Beckman Coulter has designed a flexible liquid handling system that can simultaneously automate functionality of up to three liquid handlers all on the same worksurface. Offered either preconfigured in smart solutions for targeted applications or custom-tailored to meet your laboratory's individual needs, including the ADMETox Workstation for in vitro permeability analysis of ADME/Tox Assays using the high-throughput method, PAMPA.
top
|
In-situ IR Probe in Dry box
|
|

Mettler Toledo React IR 1000
in-situ IR probe in
MBraun 130 Dry box
Contact: Robson Storey
Story Research Group
|
Mettler Toledo React IR 1000 in-situ IR probe in MBraun 130 Dry box
ReactIR™ technology provides a real-time, dynamic picture of chemistry under actual reaction conditions. Using highly specific mid-infrared spectroscopy, ReactIR™ enables both the identification and monitoring of critical reaction species and follows the changes in the reaction on a second-by-second basis.
top |
|
|

Mettler Toledo React IR 4000
in-situ IR probe in
MBraun 130 Dry box
Contact: Robson Storey
Story Research Group
|
Mettler Toledo React IR 4000 in-situ IR probe in MBraun 130 Dry box
Mettler-Toledo AutoChem ReactIR technology created a revolution in how chemists and engineers investigate chemistry and chemical processes. ReactIR technology provides a real-time, dynamic picture of chemistry under actual reaction conditions. Using highly specific mid infrared spectroscopy, ReactIR enables both the identification and monitoring of critical reaction species and follows the changes in the reaction on a second-by-second basis. The information provided by ReactIR enables reaction pathways and mechanisms to be deduced and reaction progress, kinetics and % completion to be determined. Features and Benefits include In-situ real-time data collection, investigate chemistry and processes in real-time, directly in reactor, Mid-infrared technology, deduce reaction pathways, mechanisms and kinetics with the spectral information, ReactIR Reaction Analysis software determine reaction performance, conversion, completion. Utilizes patented Comp technology including DiComp diamond ATR. Able to analyze and monitor virtually all classes of chemical reactions. Has Sealed optics, operates safely in fume hoods, mounted either on bench top or wall, Compact "Tower“ design, and preserves valuable lab space.
top
|
Real-Time PCR Detection System
|
|

MyiQ Single-Color
Real-Time PCR
Detection System
Contact: Sabine Heinhorst
Department of Chemistry
|
MyiQ Single-Color Real-Time PCR Detection System
Polymerase Chain Reaction is a technique which is used to amplify the number of copies of a specific region of DNA, in order to produce enough DNA to be adequately tested. The new MyiQ real-time PCR detection system offers an affordable alternative for the detection of common green fluorescent dyes such as FAM and SYBR Green I. This system interfaces directly with the iCycler thermal cycler, offering superior features such as thermal gradient and Peltier-effect driven performance. The MyiQ real-time PCR detection system is a perfect solution for those just getting started with this technology as well as those looking for additional instruments to handle increasing routine assay demands. This system was developed by the same experts at Bio-Rad who have pioneered performance in real-time PCR. The MyiQ delivers the same excellent-quality data as the iCycler iQ real-time detection system. Detection 585 nm FAM/SYBR filters included as well as excitation 400 nm FAM/SYBR filters and 96 Wells. Has a dynamic range of 8 orders of magnitude and the cycling system is peltier and joule.
- Innovative real-time PCR thermal gradient
- IEasy melt-curve analysis
- Customizable end-point analysis
- Sensitivity of detection down to one copy of IL-1beta
- Superb uniformity of results across all 96 wells in a SYBR Green uniformity assay
- Excellent resolution over at elast 6 orders of magnitude
- New MyiQ software
- Quantitation, melt-curve, and end-point options for data analysis
- Easy real-time PCR protocol setup
- Comprehensive end-point analysis
- Customizable trace sty
top |
|